{"product_id":"strisce-misurazione-glicemia-glucomen-areo-sensor-25-pezzi","title":"Glucomen Areo Sensor Blood Glucose Test Strips 25 Pieces","description":"\u003cp\u003e\u003c\/p\u003e\u003ch1\u003eGlucoMen\u003cbr\u003e areo \u003ci\u003eSensor\u003c\/i\u003e\n\n\u003c\/h1\u003e \u003cdiv align=\"justify\"\u003e\n\n\u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e \u003ci\u003eIn vitro\u003c\/i\u003e diagnostic medical device.\u003cbr\u003e Sensors for the quantitative determination of glucose levels in fresh capillary whole blood; for use exclusively with the GlucoMen areo 2K instrument.\u003cbr\u003e The sensors are designed for monitoring and self-monitoring of blood glucose levels in people with diabetes mellitus; they can also be used in a hospital setting by medical and healthcare personnel.\u003cbr\u003e Not intended for use in the diagnosis or screening of diabetes or for use in newborns.\u003cbr\u003e Do not change your treatment based on test results without first consulting your doctor or healthcare professional.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eGeneral characteristics\u003c\/b\u003e\u003cbr\u003e \u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"1\" width=\"500\"\u003e \u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eBlood glucose measurement\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003especificity for beta-D-glucose in blood\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eEnzymatic composition (per cm\u003csup\u003e2\u003c\/sup\u003e) of a blood glucose test strip\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e- glucose oxidase (from \u003ci\u003eAspergillus niger\u003c\/i\u003e), 3.5%\u003cbr\u003e - mediator: hexacyanoferrate (III) ion, 17.5%\u003cbr\u003e - non-reactive substances, 79%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cb\u003eUnit of measurement\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eGlucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003emg\/dL (not modifiable)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cb\u003eMeasurement range\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eGlucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e20-600 mg\/dL\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cb\u003eResponse time\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eGlucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e5 seconds\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cb\u003eSample volume\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eGlucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003e0.5 microL\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cb\u003eHematocrit acceptability range\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eGlucose\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003eautomatically corrects the measurement based on hematocrit (10-70%)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eCorrelation\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003eplasma equivalent\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eSample\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003efresh capillary whole blood\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eSensor coding\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003eauto-coding\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eHygiene\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003eautomatic test strip ejection using a dedicated eject button\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eSampling\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003eautomatic blood sample aspiration by capillarity\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eAlternative site testing (AST)\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003eallowed (palm and forearm)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003e\u003cb\u003eOperating environment\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd align=\"Center\"\u003etemperature range: 5-45°C\u003cbr\u003e humidity: 20%-90% (non-condensing)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003c\/table\u003e \u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e 1. Insert a new GlucoMen areo Sensor (white color) into the sensor insertion slot. The drop symbol will start flashing on the display and the glucose symbol \"Glu\" will appear in the lower left. If nothing appears on the display, remove the sensor, reinsert it into the slot, and wait for the drop symbol to start flashing.\u003cbr\u003e For information on how to use the lancing device, read the relevant instructions for use.\u003cbr\u003e 2. Hold the tip of the sensor in contact with the blood drop until the confirmation window fills. At that point, an audible signal will sound (if enabled) and the display will show a countdown.\u003cbr\u003e 3. Read the test results. An audible signal will announce the appearance of the test result on the screen with the glucose symbol \"Glu\".\u003cbr\u003e 4. To remove the sensor, press the eject button. The instrument will turn off.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e Keep the instrument, sensors, and other components out of reach and sight of children. Small parts can pose a choking hazard.\u003cbr\u003e Handle the vial and sensors with clean, dry hands.\u003cbr\u003e Dispose of the vial and used sensors in accordance with local regulations.\u003cbr\u003e Handling blood can be dangerous: exercise extreme caution when handling blood, sensors, lancets, and the instrument.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eStorage\u003c\/b\u003e\u003cbr\u003e Store the sensor vial in a dry place, at a temperature of 4-30°C. Do not freeze. Avoid heat and direct sunlight.\u003cbr\u003e Store all unused sensors in the original vial and after taking one out, close the cap tightly to preserve their quality. Do not transfer sensors to other containers.\u003cbr\u003e Do not use sensors beyond the expiration date.\u003cbr\u003e Do not use sensors beyond 12 months from the first opening of their vial. It is recommended to write the disposal date (date of first opening + 12 months) on the label.\u003cbr\u003e Strips in unopened packaging are valid for 24 months from the date of manufacture.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e Pack of 25 sensors.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eCode\u003c\/b\u003e 48528\u003c\/div\u003e","brand":"A.MENARINI DIAGNOSTICS","offers":[{"title":"Default Title","offer_id":57339191427416,"sku":"938766538","price":30.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/9301\/0264\/files\/938766538.jpg?v=1779320498","url":"https:\/\/www.globalpharmacy.it\/en\/products\/strisce-misurazione-glicemia-glucomen-areo-sensor-25-pezzi","provider":"Global Pharmacy","version":"1.0","type":"link"}