1
/
of
1
A.MENARINI DIAGNOSTICS
Glucomen Areo Sensor Blood Glucose Test Strips 25 Pieces
Glucomen Areo Sensor Blood Glucose Test Strips 25 Pieces
Regular price
€30,17 EUR
Regular price
€35,50 EUR
Sale price
€30,17 EUR
Taxes included.
Shipping calculated at checkout.
Quantity
Couldn't load pickup availability
MINSAN: 938766538
EAN:
DITTA: A.MENARINI DIAGNOSTICS
GlucoMen
areo Sensor
Description
In vitro diagnostic medical device.
Sensors for the quantitative determination of glucose levels in fresh capillary whole blood; for use exclusively with the GlucoMen areo 2K instrument.
The sensors are designed for monitoring and self-monitoring of blood glucose levels in people with diabetes mellitus; they can also be used in a hospital setting by medical and healthcare personnel.
Not intended for use in the diagnosis or screening of diabetes or for use in newborns.
Do not change your treatment based on test results without first consulting your doctor or healthcare professional.
General characteristics
How to use
1. Insert a new GlucoMen areo Sensor (white color) into the sensor insertion slot. The drop symbol will start flashing on the display and the glucose symbol "Glu" will appear in the lower left. If nothing appears on the display, remove the sensor, reinsert it into the slot, and wait for the drop symbol to start flashing.
For information on how to use the lancing device, read the relevant instructions for use.
2. Hold the tip of the sensor in contact with the blood drop until the confirmation window fills. At that point, an audible signal will sound (if enabled) and the display will show a countdown.
3. Read the test results. An audible signal will announce the appearance of the test result on the screen with the glucose symbol "Glu".
4. To remove the sensor, press the eject button. The instrument will turn off.
Warnings
Keep the instrument, sensors, and other components out of reach and sight of children. Small parts can pose a choking hazard.
Handle the vial and sensors with clean, dry hands.
Dispose of the vial and used sensors in accordance with local regulations.
Handling blood can be dangerous: exercise extreme caution when handling blood, sensors, lancets, and the instrument.
Storage
Store the sensor vial in a dry place, at a temperature of 4-30°C. Do not freeze. Avoid heat and direct sunlight.
Store all unused sensors in the original vial and after taking one out, close the cap tightly to preserve their quality. Do not transfer sensors to other containers.
Do not use sensors beyond the expiration date.
Do not use sensors beyond 12 months from the first opening of their vial. It is recommended to write the disposal date (date of first opening + 12 months) on the label.
Strips in unopened packaging are valid for 24 months from the date of manufacture.
Format
Pack of 25 sensors.
Code 48528
In vitro diagnostic medical device.
Sensors for the quantitative determination of glucose levels in fresh capillary whole blood; for use exclusively with the GlucoMen areo 2K instrument.
The sensors are designed for monitoring and self-monitoring of blood glucose levels in people with diabetes mellitus; they can also be used in a hospital setting by medical and healthcare personnel.
Not intended for use in the diagnosis or screening of diabetes or for use in newborns.
Do not change your treatment based on test results without first consulting your doctor or healthcare professional.
General characteristics
| Blood glucose measurement | specificity for beta-D-glucose in blood |
| Enzymatic composition (per cm2) of a blood glucose test strip | - glucose oxidase (from Aspergillus niger), 3.5% - mediator: hexacyanoferrate (III) ion, 17.5% - non-reactive substances, 79% |
| Unit of measurement | |
| Glucose | mg/dL (not modifiable) |
| Measurement range | |
| Glucose | 20-600 mg/dL |
| Response time | |
| Glucose | 5 seconds |
| Sample volume | |
| Glucose | 0.5 microL |
| Hematocrit acceptability range | |
| Glucose | automatically corrects the measurement based on hematocrit (10-70%) |
| Correlation | plasma equivalent |
| Sample | fresh capillary whole blood |
| Sensor coding | auto-coding |
| Hygiene | automatic test strip ejection using a dedicated eject button |
| Sampling | automatic blood sample aspiration by capillarity |
| Alternative site testing (AST) | allowed (palm and forearm) |
| Operating environment | temperature range: 5-45°C humidity: 20%-90% (non-condensing) |
How to use
1. Insert a new GlucoMen areo Sensor (white color) into the sensor insertion slot. The drop symbol will start flashing on the display and the glucose symbol "Glu" will appear in the lower left. If nothing appears on the display, remove the sensor, reinsert it into the slot, and wait for the drop symbol to start flashing.
For information on how to use the lancing device, read the relevant instructions for use.
2. Hold the tip of the sensor in contact with the blood drop until the confirmation window fills. At that point, an audible signal will sound (if enabled) and the display will show a countdown.
3. Read the test results. An audible signal will announce the appearance of the test result on the screen with the glucose symbol "Glu".
4. To remove the sensor, press the eject button. The instrument will turn off.
Warnings
Keep the instrument, sensors, and other components out of reach and sight of children. Small parts can pose a choking hazard.
Handle the vial and sensors with clean, dry hands.
Dispose of the vial and used sensors in accordance with local regulations.
Handling blood can be dangerous: exercise extreme caution when handling blood, sensors, lancets, and the instrument.
Storage
Store the sensor vial in a dry place, at a temperature of 4-30°C. Do not freeze. Avoid heat and direct sunlight.
Store all unused sensors in the original vial and after taking one out, close the cap tightly to preserve their quality. Do not transfer sensors to other containers.
Do not use sensors beyond the expiration date.
Do not use sensors beyond 12 months from the first opening of their vial. It is recommended to write the disposal date (date of first opening + 12 months) on the label.
Strips in unopened packaging are valid for 24 months from the date of manufacture.
Format
Pack of 25 sensors.
Code 48528
Share
