{"product_id":"pulsoximetro-da-dito-oxy-2-schermo-led-60x30-5x32-5mm-1-pezzo","title":"Oxy-2 Finger Pulse Oximeter LED Screen 60X30.5X32.5Mm 1 Piece","description":"\u003cp\u003e\u003c\/p\u003e\u003ch1\u003ePULSE OXIMETER OXY-2\u003c\/h1\u003e \u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e The Fingertip Pulse Oximeter is a non-invasive device designed for instantaneous monitoring of arterial hemoglobin saturation (SpO2) and heart rate in adults and children in home and hospital environments (including clinical use in internal\/surgical therapy, anesthesia and intensive care, etc.).\u003cbr\u003e It is not intended for continuous monitoring.\u003cbr\u003e It is compact, convenient to use and carry, and has low power consumption. The two AAA batteries supplied can be used continuously for 24 hours.\u003cbr\u003e Automatic shutdown when no signal is received within 5 seconds.\u003cbr\u003e Low battery indicator as a flashing battery icon.\u003cbr\u003e The patient simply inserts their fingertip into the device's photoelectric sensor and the Hemoglobin Saturation value immediately appears on the screen.\u003cbr\u003e \u003cbr\u003e \u003cu\u003eTechnical specifications\u003c\/u\u003e:\u003cbr\u003e - Display format: Digital tube display;\u003cbr\u003e - Screen type: LED;\u003cbr\u003e - SpO2 measurement range: 0%-100%;\u003cbr\u003e - Heart rate measurement range: 30 bpm - 250 bpm;\u003cbr\u003e - Heart rate intensity display: Bar display;\u003cbr\u003e - Power requirements: 2 x 1.5 V AAA alkaline batteries; adaptable range: 2.6 V - 3.6 V;\u003cbr\u003e - Supply current: less than 25 mA;\u003cbr\u003e - Resolution: 1% for SpO2 and 1 bpm for heart rate;\u003cbr\u003e - Measurement accuracy: ±2% in the 70%-100% SpO2 range, and irrelevant when the range is less than 70%. ±2 bpm or ±2% (select the larger) for heart rate;\u003cbr\u003e - Measurement performance in the presence of weak filling pressure: SpO2 and heart rate are correctly displayed when the heart rate-filling ratio is 0.4%. SpO2 error ±4%, heart rate error ±2 bpm or ±2% (select the larger);\u003cbr\u003e - Tolerance to external light: The difference between the value detected in the presence of artificial light, natural indoor light, and that of a dark room is less than ±1%;\u003cbr\u003e - It has a function switch. The Pulse Oximeter turns off if it does not detect fingers in the device;\u003cbr\u003e - Optical sensor: red light (wavelength is 660 nm, 6.65 mW) and infrared (wavelength is 880 nm, 6.75 mW);\u003cbr\u003e - Operating environment:\u003cbr\u003e   Temperature: 10°C - 40°C\u003cbr\u003e   Relative humidity: ≤75%\u003cbr\u003e   Atmospheric pressure: 700 hPa - 1,060 hPa.\u003cbr\u003e \u003cbr\u003e Note: The optical sensor is a light-emitting component that affects other medical devices by applying the same range of wavelengths.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eInstructions for use\u003c\/b\u003e\u003cbr\u003e Insert the two batteries in the correct direction and then replace the cover. Open the sensor. Have the patient insert their finger into the rubber-lined sensor (make sure the finger is in the correct position), then allow the sensor to close on the finger. Press the power button on the front panel. Do not move the finger and keep the patient at rest during measurement. In addition, it is recommended that the patient does not move. Measurement results are displayed directly on the display.\u003cbr\u003e \u003cbr\u003e When the recorder is in startup mode, press the button and the device is reset.\u003cbr\u003e The nails and the luminescent tube must remain on the same side.\u003cbr\u003e \u003cbr\u003e \u003cu\u003eCleaning and maintenance\u003c\/u\u003e: Replace batteries when the low battery indicator starts flashing.\u003cbr\u003e Clean the device surface before use. Wipe with medical alcohol first and then allow to air dry or wipe dry.\u003cbr\u003e Use medical alcohol to disinfect the product after use to prevent contamination for subsequent use.\u003cbr\u003e If the Pulse Oximeter is not used for a long period, remove the batteries.\u003cbr\u003e The device must be calibrated regularly (or according to the hospital's calibration schedule).\u003cbr\u003e Do not sterilize the device with high pressure.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e The finger must be positioned appropriately, otherwise this may cause inaccurate measurements.\u003cbr\u003e The SpO2 sensor and the photoelectric receiving tube must be arranged so that the patient's arteriole is in a position between the two.\u003cbr\u003e The SpO2 sensor should not be used on a site or limb tied with a blood pressure cuff or during an intravenous injection.\u003cbr\u003e Make sure the optical path is clear of optical obstructions, such as rubberized fabric.\u003cbr\u003e Excessive ambient light can affect the measurement result. This includes fluorescent lamps, double red lights, infrared radiators, direct sunlight, etc.\u003cbr\u003e Strenuous patient action or extreme electro-surgical interference can also affect accuracy.\u003cbr\u003e The patient undergoing the examination cannot wear nail polish or other cosmetics.\u003cbr\u003e Do not immerse the device in any type of liquid.\u003cbr\u003e It is recommended to keep the device in a dry environment. Humidity could reduce the device's life cycle or even damage it.\u003cbr\u003e Explosion hazard: do not use the Pulse Oximeter in environments with flammable gases such as some flammable anesthetic agents.\u003cbr\u003e DO NOT use the Pulse Oximeter while the patient is undergoing MRI or CT scans.\u003cbr\u003e a person allergic to rubber cannot use this device.\u0026gt; Please check the packaging before use to ensure that the device and its accessories fully comply with the packing list, otherwise the device may malfunction.\u003cbr\u003e Please do not measure this device with paper functional tests for relevant device information.\u003cbr\u003e Keep the Pulse Oximeter away from dust, vibrations, corrosive substances, explosive materials, high temperatures and humidity.\u003cbr\u003e If the Pulse Oximeter gets wet, please stop using it.\u003cbr\u003e When transported from a cold environment to a warm or humid environment, do not use it immediately.\u003cbr\u003e DO NOT press the front panel buttons with sharp objects.\u003cbr\u003e Disinfection of the Pulse Oximeter with high-temperature steam or pressure is not allowed. Do not immerse the Pulse Oximeter in liquids. When cleaning is required, wipe its surface with a soft cloth moistened with medical alcohol. Do not spray liquids directly on the device. When cleaning the device with water, the temperature must be below 60°C.\u003cbr\u003e Since fingers that are too thin or too cold could affect the normal SpO2 and heart rate measurement of the patient, position thicker fingers, such as the thumb and middle finger, deep enough into the device.\u003cbr\u003e Do not use the device on infants or newborns. The device is suitable for children over four years old and adults (weight must be between 15 and 110 kg).\u003cbr\u003e The device may not work for all patients. If you are unable to achieve stable measurements, discontinue use.\u003cbr\u003e The data update period is less than 5 seconds: this duration varies based on different individual heart rates.\u003cbr\u003e If any abnormality appears on the screen during the testing procedure, remove the finger and reinsert it to restore normal use.\u003cbr\u003e The normal life cycle of the device is three years from the first power-on.\u003cbr\u003e The support lanyard attached to the product is made of hypoallergenic material; if a particular group is allergic to the support lanyard, stop using it. In addition, pay attention to the use of the support lanyard, do not hang it around the neck to avoid injury to the patient.\u003cbr\u003e The device does not have a low voltage alarm function, it only indicates the battery charge level. Please change the battery when the energy level is exhausted.\u003cbr\u003e The device does not have an alarm function for particularly low parameters. Do not use the device in situations where alarms are required.\u003cbr\u003e Batteries must be removed if the device is stored for more than one month, otherwise they may leak.\u003cbr\u003e A flexible circuit connects the two parts of the device. Do not twist or pull the connection.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eStorage\u003c\/b\u003e\u003cbr\u003e Store between -40°C and 60°C. Relative humidity: ≤95%\u003cbr\u003e \u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e 1 piece.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eCode.\u003c\/b\u003e 35072\u003c\/div\u003e","brand":"GIMA SPA","offers":[{"title":"Default Title","offer_id":57340098347352,"sku":"973923081","price":19.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/9301\/0264\/files\/973923081.jpg?v=1779330101","url":"https:\/\/www.globalpharmacy.it\/en\/products\/pulsoximetro-da-dito-oxy-2-schermo-led-60x30-5x32-5mm-1-pezzo","provider":"Global Pharmacy","version":"1.0","type":"link"}