{"product_id":"pulsossimetro-oxy-watch-modello-md300c29","title":"Oxy Watch Pulse Oximeter Model Md300C29","description":"\u003cp\u003e\u003c\/p\u003e\u003ch1\u003eFingertip\u003cbr\u003e Pulse Oximeter\u003c\/h1\u003e \u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Pulse oximeter.\u003cbr\u003e The fingertip pulse oximeter is a portable and non-invasive device designed for episodic assessment of arterial hemoglobin oxygen saturation and pulse rate in adult and pediatric patients in a hospital setting. It is not intended for continuous monitoring of the aforementioned parameters.\u003cbr\u003e - OLED display for SpO2, PR, pulse bar, and waveform display.\u003cbr\u003e - Adjustable brightness, 6 display modes.\u003cbr\u003e - Low power consumption; low battery indicator.\u003cbr\u003e - Automatic shutdown; 2 AAA alkaline batteries.\u003cbr\u003e - When the signal is not detected or is too low, the pulse oximeter automatically shuts down in 8 seconds.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eInstructions for use\u003c\/b\u003e\u003cbr\u003e 1. Insert two AAA batteries into the battery compartment (Slide the battery cover horizontally in the direction of the arrow; insert two AAA Size batteries, observing the correct polarity, into the battery compartment; close the battery compartment cover. \u003cbr\u003e Note: observe battery polarity to avoid damaging the device. Remove the batteries if you do not plan to use the device for a long time.\u003cbr\u003e 2. Insert your finger into the pulse oximeter.\u003cbr\u003e 3. Press the power button on the front once.\u003cbr\u003e 4. When the oximeter is in operation, avoid moving your finger and try to remain still.\u003cbr\u003e 5. Read the values on the display according to the desired mode.\u003cbr\u003e 6. Pressing the power button for more than one second adjusts the brightness of the oximeter. There are 10 brightness levels. The default level is four.\u003cbr\u003e 7. After turning on the oximeter, each time you press the power switch, the oximeter switches to another display mode. There are 6 display modes.\u003cbr\u003e \u003cbr\u003e Inaccurate measurements may be caused by:\u003cbr\u003e 1. significant levels of dysfunctional hemoglobin (such as carboxyhemoglobin or methemoglobin);\u003cbr\u003e 2. intravascular dyes such as indocyanine green or methylene blue;\u003cbr\u003e 3. high ambient light. Cover the sensor area if necessary;\u003cbr\u003e 4. excessive patient movement;\u003cbr\u003e 5. high-frequency electrosurgical interference and defibrillators;\u003cbr\u003e 6. venous pulsations;\u003cbr\u003e 7. placement of a sensor on an extremity with a blood pressure cuff, arterial catheter, or intravascular line;\u003cbr\u003e 8. the patient has hypotension, severe vasoconstriction, severe anemia or hypothermia;\u003cbr\u003e 9. the patient is in cardiac arrest or shock;\u003cbr\u003e 10. nail polish or artificial nails;\u003cbr\u003e 11. weak pulsation (low perfusion);\u003cbr\u003e 12. low hemoglobin.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e 1. Do not use the pulse oximeter in an MRI or CT scan environment.\u003cbr\u003e 2. Do not use the pulse oximeter in situations where alarms are mandatory. The device is not equipped with an alarm.\u003cbr\u003e 3. Explosion hazard: do not use the pulse oximeter in an explosive atmosphere.\u003cbr\u003e 4. The use of the pulse oximeter is indicated only as an aid in patient assessment. The device should be used in conjunction with other methods for evaluating clinical signs and symptoms.\u003cbr\u003e 5. Frequently check the application area of the pulse oximeter to determine sensor placement and proper circulation and skin sensitivity of the patient.\u003cbr\u003e 6. This may cause inaccurate readings or skin blistering.\u003cbr\u003e 7. Before use, carefully read the manual.\u003cbr\u003e 8. The pulse oximeter has no SpO2 alarms, it is not for continuous monitoring, as indicated by the symbol.\u003cbr\u003e 9. Prolonged use or the patient's condition may require regularly changing the sensor application site. Vary the sensor application site and check skin integrity, circulatory status, and correct orientation at least every 30 minutes.\u003cbr\u003e 10. Inaccurate measurements could be caused by automatic washing, sterilization with ethylene oxide, immersion of the device in liquids, significant levels of dysfunctional hemoglobin (such as carboxyhemoglobin or methemoglobin), intravascular dyes such as indocyanine green or methylene blue.\u003cbr\u003e 11. SpO2 measurements could be negatively affected in the presence of high ambient light (avoid direct exposure of the sensor to sunlight), excessive patient movement, venous pulsations, placement of the oximeter on a finger with a simultaneous blood pressure cuff on the arm, the presence of an arterial catheter or an intravascular line, in patients with hypotension, severe vasoconstriction, severe anemia or hypothermia, in the presence of cardiac arrest or shock.\u003cbr\u003e 12. The presence of nail polish or artificial nails can cause inaccurate readings.\u003cbr\u003e 13. This equipment is not intended for use during patient transport outside the hospital environment.\u003cbr\u003e 14. This equipment should not be used or placed near other equipment.\u003cbr\u003e 15. Do not disassemble, repair, or modify the equipment without authorization.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eStorage\u003c\/b\u003e\u003cbr\u003e Store the product in a place with an ambient temperature between -20 °C and 55 °C and relative humidity below 93%.\u003cbr\u003e It is recommended to store the device in a dry place. A humid environment could damage the product.\u003cbr\u003e Device life: 60 months (when used for 15 measurements daily and for 10 minutes each measurement).\u003cbr\u003e \u003cbr\u003e \u003cb\u003eCode\u003c\/b\u003e MD300C29\u003c\/div\u003e","brand":"CA-MI SRL","offers":[{"title":"Default Title","offer_id":57389082542424,"sku":"981429285","price":43.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/9301\/0264\/files\/981429285.jpg?v=1779983365","url":"https:\/\/www.globalpharmacy.it\/en\/products\/pulsossimetro-oxy-watch-modello-md300c29","provider":"Global Pharmacy","version":"1.0","type":"link"}