{"product_id":"glucometro-iris-evolution-x-sistema-monitoraggio-glicemia","title":"Iris Evolution X Blood Glucose Monitoring System","description":"\u003cp\u003e\u003c\/p\u003e\u003ch1\u003eiris\u003cbr\u003e Evolution X\u003c\/h1\u003e \u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e A blood glucose monitoring system, designed for easy blood glucose control and to help keep values under control.\u003cbr\u003e The Iris Evolution X blood glucose test is based on measuring the electrical current caused by the reaction of glucose with the reagents on the test strip's electrode.\u003cbr\u003e The blood sample is drawn into the tip of the test strip by capillary action. The glucose in the sample then reacts with an enzyme and a mediator, generating electrons, which produce a current proportional to the glucose concentration in the sample. After the reaction time, the glucose concentration in the sample is displayed. The instrument is calibrated to display plasma concentration results.\u003cbr\u003e Intended for external use (in vitro diagnostic use) by people with diabetes and by healthcare professionals in the clinical field, in order to effectively monitor diabetes. The system should not be used for the diagnosis of diabetes.\u003cbr\u003e \u003cbr\u003e \u003cu\u003eTechnical Information\u003c\/u\u003e\u003cbr\u003e \u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"3\"\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e10 to 600 mg\/dL (0.6-33.3 mmol\/L)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003ePlasma-equivalent\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eSample\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eFresh whole blood (capillary, venous, arterial, and neonatal)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eSample volume\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eApproximately 0.5 mcL\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eTest duration\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eApproximately 5 seconds\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003ePower source\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eTwo 1.5 V AAA LR03 batteries\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eGlucose unit of measure\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eThe meter is preset to millimoles per liter (mmol\/L) or milligrams per deciliter (mg\/dL) depending on the country standard\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eMemory\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e1,000 memories with date and time\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eAutomatic shutdown\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e2 minutes after last action\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e93.5 mm x 60.5 mm x 20 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eDisplay dimensions\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e47 mm x 37 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eWeight\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eApproximately 67.4 g (with battery installed)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e5-45 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eOperating relative humidity\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e10-90% (non-condensing)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eHematocrit range\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e0-70%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eBluetooth\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eVersion 4.2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003c\/table\u003e\n\n\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e Properly set up the meter and have all necessary materials on hand before starting the test (the Iris Evolution X meter, Iris Evo test strips, and the Iris lancing device with its lancets).\u003cbr\u003e \u003cbr\u003e Wash and dry your hands thoroughly before starting the test.\u003cbr\u003e Remove a test strip from the vial or aluminum foil pouch. Carefully close the vial cap immediately after removing the test strip. Insert the test strip into the meter in the direction of the arrow. The meter will turn on after an audible signal.\u003cbr\u003e A symbol with a test strip and a flashing blood drop appears on the display, indicating that the meter is ready for testing.\u003cbr\u003e To obtain a fingertip blood sample, adjust the penetration depth to reduce pain.\u003cbr\u003e Remove the cap from the lancing device. Insert a sterile lancet into the lancing device and push it until the lancet is fully seated in the device. Hold the lancet firmly in the lancing device and twist off the lancet's safety tab, then pull the safety tab off the lancet. Keep the safety tab for later disposal of the used lancet. Carefully place the cap back on the lancing device. Avoid contact with the exposed needle. Make sure the cover is fully screwed onto the device.\u003cbr\u003e Adjust the penetration depth by rotating the lancing device's cap. There are a total of 5 penetration depth settings. To reduce pain, use the lowest setting that still allows a sufficient blood drop.\u003cbr\u003e Pull back the end to prime the lancing device. The device will click to indicate that the lancing device is now loaded and ready to obtain a blood drop.\u003cbr\u003e Press the lancing device. Push the release button to prick your fingertip. You should feel a click when the lancing device activates. Gently massage your finger from the base to the tip to obtain the desired blood volume. Avoid touching the blood drop. To reduce pain, it is recommended to prick the side of your finger. Perform the test immediately after obtaining the necessary amount of blood. Immediately bring the tip of the test strip into contact with the blood drop. The blood will be drawn into the test strip through the tip. Ensure that the test strip channel is completely filled. Keep the tip of the test strip in contact with the blood drop until the meter beeps. If the blood sample does not fill the test strip channel, do not add a second blood drop. Discard the used test strip and retest using a new test strip.\u003cbr\u003e The meter will start a 5-second countdown and the result will be displayed after an audible signal. The test result will be automatically saved in the device's memory. Please do not touch the test strip during the countdown as this may cause an error in the result.\u003cbr\u003e You can remove the used test strip by sliding the strip ejector lever forward. The instrument automatically turns off after an audible signal. Unscrew the lancing device cap. Place the lancet safety tab on a flat surface; carefully insert the lancet needle into the safety tab. Press the release button to ensure the lancing device is unloaded. Slide the eject button forward to eject the used lancet. Replace the lancing device cap.\u003cbr\u003e \u003cbr\u003e \u003cu\u003eInterpretation of results\u003c\/u\u003e\u003cbr\u003e Blood glucose values vary depending on food intake, medication dosages, health, stress, or exercise. Ideally, the goal is to control the glucose level as close as possible to a normal blood glucose level (non-diabetic).\u003cbr\u003e \u003cbr\u003e \u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"3\"\u003e\n\n\u003ctr align=\"center\"\u003e\n\n\u003ctd\u003e \u003c\/td\u003e\n\n\u003ctd\u003e\u003cb\u003eRange (mg\/dL)\u003c\/b\u003e\u003c\/td\u003e\n\n\u003ctd\u003e\u003cb\u003eRange (mmol\/L)\u003c\/b\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003eBefore a meal\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e80-130 mg\/dL\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e4.4-7.2 mmol\/L\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003ctr\u003e\n\n\u003ctd\u003e1-2 hours after start of meal\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eless than 180 mg\/dL\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003eless than 10 mmol\/L\u003c\/td\u003e\n\n\n\u003c\/tr\u003e \u003c\/table\u003eExpected blood glucose levels for most non-pregnant adults with diabetes.\u003cbr\u003e \u003cbr\u003e If the blood glucose reading is less than 50 mg\/dL (2.8 mmol\/L) or if LO [less than 10 mg\/dL (0.6 mmol\/L)] is displayed on the meter, contact your doctor as soon as possible.\u003cbr\u003e If the test result is greater than 250 mg\/dL (13.9 mmol\/L) or if HI [greater than 600 mg\/dL (33.3 mmol\/L)] is displayed on the meter, contact your doctor as soon as possible.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e The Iris Evolution X meter, Iris® Evo test strips, and control solutions have been designed, tested, and their effectiveness proven to provide accurate blood glucose measurements. Do not use components from other brands.\u003cbr\u003e Fresh capillary blood can be collected in tubes containing sodium heparin or lithium heparin if the blood sample is used within 10 minutes. Do not use sodium fluoride\/oxalate or other anticoagulants or preservatives.\u003cbr\u003e Use whole blood only. Do not use with serum or plasma samples.\u003cbr\u003e Very high hematocrit levels (above 70%) can cause inaccurate results.\u003cbr\u003e Abnormally high levels of vitamin C and other reducing substances will produce inaccurate blood glucose results.\u003cbr\u003e The system can accurately read glucose in whole blood in the range of 10 to 600 mg\/dL (0.6-33.3 mmol\/L).\u003cbr\u003e Fatty substances [triglycerides up to 3,000 mg\/dL (166.7 mmol\/L) or cholesterol up to 500 mg\/dL (27.7 mmol\/L)] have no significant effect on blood glucose test results.\u003cbr\u003e Seriously ill subjects should not perform blood glucose testing with the Iris Evolution X blood glucose monitoring system.\u003cbr\u003e Blood samples from patients in shock, with severe dehydration, or from hyperosmolar patients (with or without ketosis) have not been tested and are not recommended for testing with the Iris Evolution X system.\u003cbr\u003e Carefully dispose of blood samples and materials. Treat all blood samples as if they were infectious materials. Follow appropriate precautions and comply with all local regulations when disposing of materials.\u003cbr\u003e \u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e 1 piece\u003cbr\u003e \u003cbr\u003e \u003cb\u003eCode.\u003c\/b\u003e VGM77\u003c\/div\u003e","brand":"ALPHA PHARMA SERVICE SRL","offers":[{"title":"Default Title","offer_id":57340384248152,"sku":"985667599","price":45.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0968\/9301\/0264\/files\/985667599.jpg?v=1779340983","url":"https:\/\/www.globalpharmacy.it\/en\/products\/glucometro-iris-evolution-x-sistema-monitoraggio-glicemia","provider":"Global Pharmacy","version":"1.0","type":"link"}