Fisiochamber Vision Plus Antistatic Inhalation Chamber with Panda Mask for Infants
Fisiochamber Vision Plus Antistatic Inhalation Chamber with Panda Mask for Infants
Regular price
€25,07 EUR
Regular price
€29,50 EUR
Sale price
€25,07 EUR
Taxes included.
Shipping calculated at checkout.
Quantity
Couldn't load pickup availability
MINSAN: 975427434
EAN: 6970057855707
DITTA: TRED SRL
FISIOCHAMBER VISION PLUS
INFANT 0-3 years
Description
Antistatic chamber for use with pressurized metered dose inhalers (MDIs).
Directions for use
Before use, carefully check all parts, valves, and air inlets. Replace if defective.
Remove the cap from the metered dose inhaler (MDI). Shake the MDI.
Insert the MDI into the "Proper Fit" universal adapter and ensure a good seal.
Remove the cap from the inhalation chamber.
Insert the mask into the mouthpiece of the inhalation chamber.
Verify that the safety exhalation valve opens (otherwise replace the mask).
Apply the mask to the face and ensure a good seal.
If the patient can cooperate, apply the mouthpiece only in the mouth and ensure it is properly sealed.
Inhale and exhale normally.
Then press the inhaler only once and begin to inhale slowly.
Carefully observe the VISION VALVE: its movement indicates the act of inhalation.
After pressing the inhaler, keep the mask firmly against the face for at least 5 breaths.
Before pressing the inhaler again, wait and repeat this step following the instructions of the inhaler or doctor. Always follow the dosage prescribed by the doctor.
Cleaning, disinfection and sterilization
Wash before first use and at least once a week following the instructions.
Remove all parts as indicated and open the chamber.
Submerge the parts for 15 minutes in clean lukewarm water and mild detergent.
Gently agitate.
Rinse all parts with clean water. Shake off excess water and air dry.
Do not use cloths to dry.
Before reassembling, make sure the parts are thoroughly dry.
Reassemble the parts as indicated.
Disinfection: immerse in 3% hydrogen peroxide for 30 minutes.
Sterilization: sterilizable with a 121 °C steam cycle or with ETO gas or plasma system.
Warnings
- Always follow instructions before each use.
- Do not leave Fisio Chamber Vision or parts of it within reach of children: some parts are small enough and could be swallowed.
- The product must be replaced after a maximum of 2 years of continuous use.
- Replace the product when it is no longer in its original conditions of use, due to any damage, valve seal, environmental and storage conditions, and frequency of use.
- The use and sale of Fisio Chamber Vision are permitted under strict supervision of personnel trained in its use.
- Monitor the patient during use.
- To maintain maximum efficiency of the device, we recommend replacing the valve block every 12 months.
Storage
Store the product in a dry and clean place.
Relative humidity 30% - 80%.
Storage temperature 0 °C-40 °C.
Avoid prolonged exposure to high temperatures.
Do not expose to: organic solvents, ionizing radiation, ultraviolet light, direct light, and sunlight.
Shelf life of intact packaging: 60 months.
Shelf life after opening: 24 months.
Code. KM 1322B
Antistatic chamber for use with pressurized metered dose inhalers (MDIs).
Directions for use
Before use, carefully check all parts, valves, and air inlets. Replace if defective.
Remove the cap from the metered dose inhaler (MDI). Shake the MDI.
Insert the MDI into the "Proper Fit" universal adapter and ensure a good seal.
Remove the cap from the inhalation chamber.
Insert the mask into the mouthpiece of the inhalation chamber.
Verify that the safety exhalation valve opens (otherwise replace the mask).
Apply the mask to the face and ensure a good seal.
If the patient can cooperate, apply the mouthpiece only in the mouth and ensure it is properly sealed.
Inhale and exhale normally.
Then press the inhaler only once and begin to inhale slowly.
Carefully observe the VISION VALVE: its movement indicates the act of inhalation.
After pressing the inhaler, keep the mask firmly against the face for at least 5 breaths.
Before pressing the inhaler again, wait and repeat this step following the instructions of the inhaler or doctor. Always follow the dosage prescribed by the doctor.
Cleaning, disinfection and sterilization
Wash before first use and at least once a week following the instructions.
Remove all parts as indicated and open the chamber.
Submerge the parts for 15 minutes in clean lukewarm water and mild detergent.
Gently agitate.
Rinse all parts with clean water. Shake off excess water and air dry.
Do not use cloths to dry.
Before reassembling, make sure the parts are thoroughly dry.
Reassemble the parts as indicated.
Disinfection: immerse in 3% hydrogen peroxide for 30 minutes.
Sterilization: sterilizable with a 121 °C steam cycle or with ETO gas or plasma system.
Warnings
- Always follow instructions before each use.
- Do not leave Fisio Chamber Vision or parts of it within reach of children: some parts are small enough and could be swallowed.
- The product must be replaced after a maximum of 2 years of continuous use.
- Replace the product when it is no longer in its original conditions of use, due to any damage, valve seal, environmental and storage conditions, and frequency of use.
- The use and sale of Fisio Chamber Vision are permitted under strict supervision of personnel trained in its use.
- Monitor the patient during use.
- To maintain maximum efficiency of the device, we recommend replacing the valve block every 12 months.
Storage
Store the product in a dry and clean place.
Relative humidity 30% - 80%.
Storage temperature 0 °C-40 °C.
Avoid prolonged exposure to high temperatures.
Do not expose to: organic solvents, ionizing radiation, ultraviolet light, direct light, and sunlight.
Shelf life of intact packaging: 60 months.
Shelf life after opening: 24 months.
Code. KM 1322B