Skip to product information
1 of 1

TELEFLEX MEDICAL SRL

Foley Indwelling Catheter Silasil Plus Adult For 3-Way Irrigation With Silicone Balloon 2 Lateral Eyes Ch20 1 Piece

Foley Indwelling Catheter Silasil Plus Adult For 3-Way Irrigation With Silicone Balloon 2 Lateral Eyes Ch20 1 Piece

Regular price €7,50 EUR
Regular price €8,82 EUR Sale price €7,50 EUR
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity

MINSAN: 907102634

EAN: 4026704075591

DITTA: TELEFLEX MEDICAL SRL

Bladder Catheter
SILASIL

Description
Balloon catheter for routine transurethral drainage or for postoperative transurethral drainage and bladder irrigation under medical supervision.
These catheters are made of silicone. Only use sterile water or a sterile 10% glycerin solution to inflate the balloons. The pre-filled syringe should only be used to inflate the balloons, not for injections.
Catheters designed for postoperative drainage following continent urinary diversion procedures using neobladders or orthotopic pouches.

Instructions for use
Equipped with a hydrophilic coating. It is recommended to moisten with sterile water or sterile physiological saline solution before use.
Refer to the product's instructions for use.
Dwell time: 30 days.
Clinically, the actual in situ dwell time is closely related primarily to the patient's condition, such as urine concentration and pH, infections, the patient's tendency to form stones, and metabolic deficiency. Based on these parameters, the dwell time may vary from patient to patient.

Composition
The construction material is SILASIL (silicone-latex-silicone).
Important: the latex layer is in the inner portion of the catheter; the urethral wall and urine are always in contact with a silicone layer.
DEHP-free, drug-free, substance-free, and biological tissue-free.

Warnings
Possible complications
In the case of non-deflatable balloons, cut the catheter shaft at the bifurcation or puncture the balloon according to established procedures. If the balloon breaks, all fragments must be removed from the bladder.
Catheter-associated urinary tract infections, urgency and tenesmus, irritation of the urethral mucosa, and catheter blockage due to encrustation are documented complications. Incorrect catheter placement can cause urethral damage if the balloon is inflated within the urethra.
Do not use silicone-based lubricants for silicone catheters. Given the possibility of diffusion, it is recommended to check the volume of balloons inflated with sterile water at least once a week.
These products are made of natural latex and can be sources of allergic reactions. Do not use petroleum-based lubricants. Only use sterile water to inflate the balloons.
Before use, visually inspect the catheter for any mechanical damage and check for leaks.
Do not overinflate the balloons. Excessive aspiration can cause the inflation channel to collapse. Sterility is guaranteed only if the packaging is unopened and intact.
Single-use: do not reuse, reprocess, or re-sterilize. Reuse of the device may pose a risk of injury and/or serious infections that can be fatal. Reprocessing of single-use medical devices can lead to degraded performance or loss of functionality.

Contraindications
Latex allergy. Insurmountable urethral passages. Excessive urethral stricture, false passage.

Storage
Keep away from sunlight and keep dry.
Store at room temperature, away from direct light exposure. Prolonged exposure to fluorescent light, sunlight, or heat will damage the device.
Sterilization shelf life: 5 years from the date of manufacture.

Format
Product Code CH Number of ways Tip Balloon ml Length cm Number of holes Number of pieces
850241 12-24 2 cylindrical 10 40 2 1
850243 18-22 3 cylindrical 10 40 2 1
View full details