Colpharma Air 2000 Pocket Mesh Nebulizer
Colpharma Air 2000 Pocket Mesh Nebulizer
Regular price
€72,16 EUR
Regular price
€84,90 EUR
Sale price
€72,16 EUR
Taxes included.
Shipping calculated at checkout.
Quantity
Couldn't load pickup availability
MINSAN: 951047455
EAN: 6970384253757
DITTA: COLPHARMA SRL
COLPHARMA
Air 200
POCKET MESH
Description
CE Medical Device (EU Dir. 93/42/EEC) Class IIa.
MESH nebulizer for aerosol therapy that nebulizes the drug for the treatment of airways. Air 2000 POCKET is portable, compact, handy and lightweight. Completely silent, it ensures maximum comfort during therapy. It runs on batteries or with a USB cable. It comes with a practical carrying case.
The MESH is a metallic 'mesh' characterized by over 3,600 micro-holes. The drug passes through the MESH, which is vibrated at high frequency, nebulizing the drug into very fine particles, effective for aerosol therapy.
With LED light to indicate operating status:
- steady green: device in operation;
- steady orange: low battery;
- flashing green: self-cleaning mode.
Technical specifications
Power supply: 2 AA batteries or adapter (AC/DC 5V)
Rated power: <3 W
Ultrasound frequency: approx. 110 kHz
Safety level: Type BF, Class II
Nebulization rate: approx. 0.30 ml/min.
Maximum filling volume: 8 ml
Minimum filling volume: 0.5 ml
MMAD: approx. 3.5 nm
FPD: approx. 80%
Low battery indication: 1.9 V ±0.2 V
Service life:
- Power unit: 3 years
- Nebulizing unit: 180 hours
- Accessories: 1 year
Automatic shutdown: in absence of liquid
Operating temperature and humidity: between 10°C and 40°C and between 30% and 85%
Storage temperature and humidity: between -10°C and 40°C and between 10% and 85%
Altitude: ≤2,000 m
IP Class: IP22
Dimensions: 98 mm x 45 mm x 73 mm
Self-cleaning mode: Yes
Reference standards: EN 13544-1+A1:2009, EN 62304, IEC 61000-4-2:2008, IEC 61000-4-4:2012, IEC 61000-4-5:2005, IEC 61000-4-11:2004, IEC 61000-4-8:2009, IEC 61000-4-6:2013, IEC 61000-4-3:2006+A1:2007+A2:2010, IEC 60601-1-2:2014, IEC 61000-3-2, IEC 61000-3-3
Assembly
1. Install the nebulizer unit. Push the nebulizer unit in the direction indicated by the arrow into the slot of the power unit. A "click" sound indicates that it is installed in position. If the nebulizer unit is not installed correctly, nebulization may not be effective.
2. Remove the nebulizer unit from the power unit. Press and hold the PRESS button located on the power unit and pull the nebulizer unit out of the power unit. Warning: to avoid damage to the device, do not remove the nebulizer unit without first pressing the PRESS button.
How to use
When using the device for the first time, it is recommended to clean it as described in the 'Cleaning and disinfection' section.
1. Open the medication chamber by holding the power unit with one hand and grasping the lid tab with the thumb and forefinger of the other hand to unlock it upwards.
2. Add the amount of medication prescribed by the doctor. The maximum and minimum liquid volumes are 8 ml and 0.5 ml respectively. Do not exceed the limit (max. 8 ml).
3. Close the lid of the medication chamber: a "click" sound indicates correct closure.
4. Install the mouthpiece: connect the mouthpiece to the nebulizer unit fitting. To use the mouthpiece, close your lips slightly so as not to disperse the flow of the nebulized medication.
5. Install the mask: connect the mask to the nebulizer unit fitting. Bring the mask close to your face and adjust the elastic straps to secure it properly.
6. Operating method: press the ON/OFF button to turn on the device. The operating LED will light up with a steady green light and the device will start nebulizing.
7. Inhalation: holding the device, slowly inhale the nebulized medication, breathing through your nose or mouth. Slow and steady breathing promotes the inhalation of aerosol medications into the respiratory tract.
The duration of each inhalation should not exceed 15/20 minutes.
For effective aerosol therapy, it is necessary to be calm, relaxed and seated. An uncomfortable posture and inconsistent breathing can cause airway obstruction. Use the mouthpiece correctly to prevent medication accumulation on the tongue. Press the ON/OFF button when you want to stop aerosol therapy. The device turns off automatically when the medication is depleted. When there are many bubbles between the medication and the Mesh nebulizer, the device cannot nebulize the medication. You can first turn off the device, then gently shake the nebulizer. Finally, restart the device. To ensure normal nebulization of the medication, keep the device vertical or tilt it slightly towards the Mesh nebulizer. If the operating device is tilted to the point that the liquid is not in contact with the Mesh nebulizer, the device turns off after 10 seconds. Tilt the nebulizer slightly towards you when the solution is almost depleted, to ensure that the residual solution remains in contact with the Mesh nebulizer to be completely nebulized. A high viscosity solution can cause poor nebulization or clogging of the Mesh nebulizer. In this case, turn off the device and rinse the accumulated solution with distilled water.
1. At the end of the treatment, press the ON/OFF button to turn off the device. Remove the mouthpiece or mask from the nebulizer unit. 2. Pour out any remaining medication and clean the device. For more information, see the Cleaning and disinfection section.
Cleaning and disinfection
Cleaning
The nebulizer unit and accessories (mouthpiece or mask) must be cleaned and disinfected after each application. After each use, remove the mouthpiece or mask from the nebulizer unit. Open the top cover of the nebulizer unit to remove any residual medication. Then add tap water to the medication chamber and shake gently, then pour out the water. Be careful not to wet the outer surface of the device. Add tap water again and close the nebulizer. By pressing the ON/OFF button and holding it for 5 seconds, the indicator will flash green and the device will enter self-cleaning mode. After cleaning for 2-3 minutes, press the ON/OFF button to stop the cleaning mode. Finally, pour out the remaining water. Remove the nebulizer unit from the power unit. Disconnect the USB cable from the power unit if you are using USB power. Wash and rinse the nebulizer unit with distilled water (the power unit should not be washed). Shake off excess water and allow the parts to air dry completely on a clean, dry towel. Do not touch the Mesh nebulizer with fingers, cotton swabs or other objects. If necessary, use a clean gauze or towel to remove stains on the power unit. Make sure all cleaned parts are completely dry before storing or using them.
The power unit contains electronic parts and electrodes. Do not immerse the power unit in water or rinse it with water. Otherwise, electric shocks or current leakage may occur, resulting in device malfunction. Do not wash parts in a dishwasher. Do not use a microwave oven to dry parts.
When the Mesh nebulizer is severely clogged and cannot be cleaned with the methods described above, you can try the following method: add boiling water and a few drops of white vinegar to the medication chamber and activate the cleaning mode. If the Mesh nebulizer remains clogged, replace the nebulizer unit. Clean the mask and mouthpiece with a neutral detergent before first use and after each use. Hand wash the mask and mouthpiece in warm water (30°C) with a neutral detergent and rub gently for at least 30 seconds. Rinse thoroughly with distilled water. Allow them to air dry and keep them away from direct sunlight. Make sure the nebulizer unit and accessories are completely dry and there is no residual liquid in the nebulizer unit before storing them.
Disinfection with alcohol
Rinse the nebulizer unit and accessories with distilled water. Immerse the nebulizer unit and accessories in 75% ethyl alcohol for 10 minutes. Rinse the nebulizer unit and accessories again with distilled water, shake off excess water and allow the parts to air dry completely on a clean, dry towel. Make sure all parts are clean and dry before storing or using them. Alcohol is highly flammable. Do not use alcohol near open flames or smoke. Do not rinse or immerse the power unit, power adapter or USB cable in any liquid. Before storing the device, make sure the nebulizer unit and accessories are completely dry and there is no residual liquid in the nebulizer unit.
Warnings
Read the instructions carefully before using this device. Like all medical devices, this product may become unusable due to a power outage, depleted batteries or a mechanical problem. It is recommended to have spare batteries and a backup device available if therapy cannot be postponed. When using electrical products, basic safety precautions must always be followed. As with any electrical device, pay particular attention to children. Use this device only with medications prescribed by your doctor and follow the prescribed dosage, duration and frequency of therapy. The nebulizer is intended exclusively for aerosol therapy; any other application of the device is improper and dangerous. The manufacturer is not responsible for any damage caused by improper or incorrect use. The device is not suitable for anesthesia and pulmonary ventilation. The device must only be used with the original accessories indicated in this user manual. Do not share the nebulizer with others. This product (including mask and mouthpiece) must be used by only one patient.
Before use, ensure that the device and its parts and components (e.g. mouthpiece and mask) are assembled correctly as indicated in these instructions for use. Clean and disinfect the nebulizer and accessories (mouthpiece or mask) as indicated in the 'Cleaning and disinfection' section. Make sure the nebulizer and accessories have been cleaned and disinfected correctly before use to avoid possible contamination.
The patient is the intended operator of the nebulizer. Adult supervision is required when the device is used by children and people who require special assistance. This device is intended for human use only.
For safety reasons, always disconnect the USB cable from the USB port in the following circumstances:
- if the power adapter is damaged;
- if a malfunction occurs during operation;
- before cleaning the device;
- immediately after use.
Do not use the device if you believe it is damaged or if you notice anything unusual. Do not attempt to open, repair or modify this device. Do not attempt to clean the Mesh nebulizer with foreign objects to avoid damaging it. This device is built with delicate components and must be handled with care.
Never use this device when the ambient temperature is above 40°C. Protect the device from: water and humidity, extreme temperatures, bumps and falls, contamination and dust, direct sunlight, heat and cold.
Store the device and its accessories in a clean place. Do not shake the nebulizer during operation. Do not use and store this device in the presence of smoke and gas. Do not use leftover medication in the nebulizer but always use new medication. Do not handle the power adapter with wet hands. Never use the device if the USB cable or power adapter are wet. Do not pull the power adapter from the socket by pulling the cable. Do not swallow small parts of the nebulizer. Do not wash the power unit, adapter or USB cable with water. If liquid is spilled on the power unit or adapter, clean them immediately. Do not immerse the power unit in water or other liquids and protect it from splashes of water or other liquids. Never use the device in humid environments such as the bathroom. Do not use the device near strong electromagnetic fields such as mobile phones or radio installations. Maintain a minimum distance of 3.3 m from other appliances when using this device. When connecting the power supply, check that the power supply voltage at the socket is correct and make sure that inserting the plug does not cause an overload. Disconnect the power supply after using the device and never leave a device under voltage unattended. Make sure that children do not use the device without adult supervision. Some parts are small and could be swallowed. Pay attention to the risk of strangulation in the presence of cables or tubes. Electronic devices must be disposed of in accordance with local regulations and not with household waste. The use of this device does not replace consulting your doctor.
Do not swallow the aerosol medication. Avoid shaking the device forcefully during use to prevent malfunctions such as automatic shutdown.
Maintenance, storage and service
Make sure there is no residual liquid in the nebulizer unit. Make sure the nebulizer unit has been thoroughly cleaned and disinfected after each use. Store the device and accessories in a clean and safe place. Remove the batteries if the device will not be used for a prolonged period. Otherwise, damage due to battery leakage may occur. Remove the batteries if you want to take the device with you when you are away from home or traveling. Protect the device from direct sunlight and impacts. Never place the device in water, under running water or in a very humid environment. Keep the device away from heating and open flames. Protect the device from contact with corrosive liquids. Never dry the device and its accessories with a microwave oven. Never wrap the power cord around the device. Always use or store the device in an environment where the temperature and humidity comply with the requirements specified in the 'Technical specifications' section, otherwise the device may not function correctly. If the device does not work, look for solutions in the 'Malfunctions and actions to be taken' section. Do not use the device in places where it may be exposed to flammable gases. This device complies with EMC standard IEC60601-1-2. However, if used together with other medical devices or electrical equipment, these may affect the operation of one of the devices. Do not use the device together with other medical devices or electrical equipment.
Format
The product contains: Nebulizer unit, power unit, mouthpiece, adult mask, pediatric mask, USB cable, 2 AA batteries, storage bag, user manual.
Code 12395
CE Medical Device (EU Dir. 93/42/EEC) Class IIa.
MESH nebulizer for aerosol therapy that nebulizes the drug for the treatment of airways. Air 2000 POCKET is portable, compact, handy and lightweight. Completely silent, it ensures maximum comfort during therapy. It runs on batteries or with a USB cable. It comes with a practical carrying case.
The MESH is a metallic 'mesh' characterized by over 3,600 micro-holes. The drug passes through the MESH, which is vibrated at high frequency, nebulizing the drug into very fine particles, effective for aerosol therapy.
With LED light to indicate operating status:
- steady green: device in operation;
- steady orange: low battery;
- flashing green: self-cleaning mode.
Technical specifications
Power supply: 2 AA batteries or adapter (AC/DC 5V)
Rated power: <3 W
Ultrasound frequency: approx. 110 kHz
Safety level: Type BF, Class II
Nebulization rate: approx. 0.30 ml/min.
Maximum filling volume: 8 ml
Minimum filling volume: 0.5 ml
MMAD: approx. 3.5 nm
FPD: approx. 80%
Low battery indication: 1.9 V ±0.2 V
Service life:
- Power unit: 3 years
- Nebulizing unit: 180 hours
- Accessories: 1 year
Automatic shutdown: in absence of liquid
Operating temperature and humidity: between 10°C and 40°C and between 30% and 85%
Storage temperature and humidity: between -10°C and 40°C and between 10% and 85%
Altitude: ≤2,000 m
IP Class: IP22
Dimensions: 98 mm x 45 mm x 73 mm
Self-cleaning mode: Yes
Reference standards: EN 13544-1+A1:2009, EN 62304, IEC 61000-4-2:2008, IEC 61000-4-4:2012, IEC 61000-4-5:2005, IEC 61000-4-11:2004, IEC 61000-4-8:2009, IEC 61000-4-6:2013, IEC 61000-4-3:2006+A1:2007+A2:2010, IEC 60601-1-2:2014, IEC 61000-3-2, IEC 61000-3-3
Assembly
1. Install the nebulizer unit. Push the nebulizer unit in the direction indicated by the arrow into the slot of the power unit. A "click" sound indicates that it is installed in position. If the nebulizer unit is not installed correctly, nebulization may not be effective.
2. Remove the nebulizer unit from the power unit. Press and hold the PRESS button located on the power unit and pull the nebulizer unit out of the power unit. Warning: to avoid damage to the device, do not remove the nebulizer unit without first pressing the PRESS button.
How to use
When using the device for the first time, it is recommended to clean it as described in the 'Cleaning and disinfection' section.
1. Open the medication chamber by holding the power unit with one hand and grasping the lid tab with the thumb and forefinger of the other hand to unlock it upwards.
2. Add the amount of medication prescribed by the doctor. The maximum and minimum liquid volumes are 8 ml and 0.5 ml respectively. Do not exceed the limit (max. 8 ml).
3. Close the lid of the medication chamber: a "click" sound indicates correct closure.
4. Install the mouthpiece: connect the mouthpiece to the nebulizer unit fitting. To use the mouthpiece, close your lips slightly so as not to disperse the flow of the nebulized medication.
5. Install the mask: connect the mask to the nebulizer unit fitting. Bring the mask close to your face and adjust the elastic straps to secure it properly.
6. Operating method: press the ON/OFF button to turn on the device. The operating LED will light up with a steady green light and the device will start nebulizing.
7. Inhalation: holding the device, slowly inhale the nebulized medication, breathing through your nose or mouth. Slow and steady breathing promotes the inhalation of aerosol medications into the respiratory tract.
The duration of each inhalation should not exceed 15/20 minutes.
For effective aerosol therapy, it is necessary to be calm, relaxed and seated. An uncomfortable posture and inconsistent breathing can cause airway obstruction. Use the mouthpiece correctly to prevent medication accumulation on the tongue. Press the ON/OFF button when you want to stop aerosol therapy. The device turns off automatically when the medication is depleted. When there are many bubbles between the medication and the Mesh nebulizer, the device cannot nebulize the medication. You can first turn off the device, then gently shake the nebulizer. Finally, restart the device. To ensure normal nebulization of the medication, keep the device vertical or tilt it slightly towards the Mesh nebulizer. If the operating device is tilted to the point that the liquid is not in contact with the Mesh nebulizer, the device turns off after 10 seconds. Tilt the nebulizer slightly towards you when the solution is almost depleted, to ensure that the residual solution remains in contact with the Mesh nebulizer to be completely nebulized. A high viscosity solution can cause poor nebulization or clogging of the Mesh nebulizer. In this case, turn off the device and rinse the accumulated solution with distilled water.
1. At the end of the treatment, press the ON/OFF button to turn off the device. Remove the mouthpiece or mask from the nebulizer unit. 2. Pour out any remaining medication and clean the device. For more information, see the Cleaning and disinfection section.
Cleaning and disinfection
Cleaning
The nebulizer unit and accessories (mouthpiece or mask) must be cleaned and disinfected after each application. After each use, remove the mouthpiece or mask from the nebulizer unit. Open the top cover of the nebulizer unit to remove any residual medication. Then add tap water to the medication chamber and shake gently, then pour out the water. Be careful not to wet the outer surface of the device. Add tap water again and close the nebulizer. By pressing the ON/OFF button and holding it for 5 seconds, the indicator will flash green and the device will enter self-cleaning mode. After cleaning for 2-3 minutes, press the ON/OFF button to stop the cleaning mode. Finally, pour out the remaining water. Remove the nebulizer unit from the power unit. Disconnect the USB cable from the power unit if you are using USB power. Wash and rinse the nebulizer unit with distilled water (the power unit should not be washed). Shake off excess water and allow the parts to air dry completely on a clean, dry towel. Do not touch the Mesh nebulizer with fingers, cotton swabs or other objects. If necessary, use a clean gauze or towel to remove stains on the power unit. Make sure all cleaned parts are completely dry before storing or using them.
The power unit contains electronic parts and electrodes. Do not immerse the power unit in water or rinse it with water. Otherwise, electric shocks or current leakage may occur, resulting in device malfunction. Do not wash parts in a dishwasher. Do not use a microwave oven to dry parts.
When the Mesh nebulizer is severely clogged and cannot be cleaned with the methods described above, you can try the following method: add boiling water and a few drops of white vinegar to the medication chamber and activate the cleaning mode. If the Mesh nebulizer remains clogged, replace the nebulizer unit. Clean the mask and mouthpiece with a neutral detergent before first use and after each use. Hand wash the mask and mouthpiece in warm water (30°C) with a neutral detergent and rub gently for at least 30 seconds. Rinse thoroughly with distilled water. Allow them to air dry and keep them away from direct sunlight. Make sure the nebulizer unit and accessories are completely dry and there is no residual liquid in the nebulizer unit before storing them.
Disinfection with alcohol
Rinse the nebulizer unit and accessories with distilled water. Immerse the nebulizer unit and accessories in 75% ethyl alcohol for 10 minutes. Rinse the nebulizer unit and accessories again with distilled water, shake off excess water and allow the parts to air dry completely on a clean, dry towel. Make sure all parts are clean and dry before storing or using them. Alcohol is highly flammable. Do not use alcohol near open flames or smoke. Do not rinse or immerse the power unit, power adapter or USB cable in any liquid. Before storing the device, make sure the nebulizer unit and accessories are completely dry and there is no residual liquid in the nebulizer unit.
Warnings
Read the instructions carefully before using this device. Like all medical devices, this product may become unusable due to a power outage, depleted batteries or a mechanical problem. It is recommended to have spare batteries and a backup device available if therapy cannot be postponed. When using electrical products, basic safety precautions must always be followed. As with any electrical device, pay particular attention to children. Use this device only with medications prescribed by your doctor and follow the prescribed dosage, duration and frequency of therapy. The nebulizer is intended exclusively for aerosol therapy; any other application of the device is improper and dangerous. The manufacturer is not responsible for any damage caused by improper or incorrect use. The device is not suitable for anesthesia and pulmonary ventilation. The device must only be used with the original accessories indicated in this user manual. Do not share the nebulizer with others. This product (including mask and mouthpiece) must be used by only one patient.
Before use, ensure that the device and its parts and components (e.g. mouthpiece and mask) are assembled correctly as indicated in these instructions for use. Clean and disinfect the nebulizer and accessories (mouthpiece or mask) as indicated in the 'Cleaning and disinfection' section. Make sure the nebulizer and accessories have been cleaned and disinfected correctly before use to avoid possible contamination.
The patient is the intended operator of the nebulizer. Adult supervision is required when the device is used by children and people who require special assistance. This device is intended for human use only.
For safety reasons, always disconnect the USB cable from the USB port in the following circumstances:
- if the power adapter is damaged;
- if a malfunction occurs during operation;
- before cleaning the device;
- immediately after use.
Do not use the device if you believe it is damaged or if you notice anything unusual. Do not attempt to open, repair or modify this device. Do not attempt to clean the Mesh nebulizer with foreign objects to avoid damaging it. This device is built with delicate components and must be handled with care.
Never use this device when the ambient temperature is above 40°C. Protect the device from: water and humidity, extreme temperatures, bumps and falls, contamination and dust, direct sunlight, heat and cold.
Store the device and its accessories in a clean place. Do not shake the nebulizer during operation. Do not use and store this device in the presence of smoke and gas. Do not use leftover medication in the nebulizer but always use new medication. Do not handle the power adapter with wet hands. Never use the device if the USB cable or power adapter are wet. Do not pull the power adapter from the socket by pulling the cable. Do not swallow small parts of the nebulizer. Do not wash the power unit, adapter or USB cable with water. If liquid is spilled on the power unit or adapter, clean them immediately. Do not immerse the power unit in water or other liquids and protect it from splashes of water or other liquids. Never use the device in humid environments such as the bathroom. Do not use the device near strong electromagnetic fields such as mobile phones or radio installations. Maintain a minimum distance of 3.3 m from other appliances when using this device. When connecting the power supply, check that the power supply voltage at the socket is correct and make sure that inserting the plug does not cause an overload. Disconnect the power supply after using the device and never leave a device under voltage unattended. Make sure that children do not use the device without adult supervision. Some parts are small and could be swallowed. Pay attention to the risk of strangulation in the presence of cables or tubes. Electronic devices must be disposed of in accordance with local regulations and not with household waste. The use of this device does not replace consulting your doctor.
Do not swallow the aerosol medication. Avoid shaking the device forcefully during use to prevent malfunctions such as automatic shutdown.
Maintenance, storage and service
Make sure there is no residual liquid in the nebulizer unit. Make sure the nebulizer unit has been thoroughly cleaned and disinfected after each use. Store the device and accessories in a clean and safe place. Remove the batteries if the device will not be used for a prolonged period. Otherwise, damage due to battery leakage may occur. Remove the batteries if you want to take the device with you when you are away from home or traveling. Protect the device from direct sunlight and impacts. Never place the device in water, under running water or in a very humid environment. Keep the device away from heating and open flames. Protect the device from contact with corrosive liquids. Never dry the device and its accessories with a microwave oven. Never wrap the power cord around the device. Always use or store the device in an environment where the temperature and humidity comply with the requirements specified in the 'Technical specifications' section, otherwise the device may not function correctly. If the device does not work, look for solutions in the 'Malfunctions and actions to be taken' section. Do not use the device in places where it may be exposed to flammable gases. This device complies with EMC standard IEC60601-1-2. However, if used together with other medical devices or electrical equipment, these may affect the operation of one of the devices. Do not use the device together with other medical devices or electrical equipment.
Format
The product contains: Nebulizer unit, power unit, mouthpiece, adult mask, pediatric mask, USB cable, 2 AA batteries, storage bag, user manual.
Code 12395
Share